Environmental Error Logout Frames

These logout frames are used for all (Tru64 UNIX, OpenVMS and Alpha 21264 processor SCB 680) system environmental correctable and uncorrectable errors.


Environmental Error Logout Frame

The operating system may choose to log additional information such as PCI configuration and various registers in the PCI-ISA bridge chip.

This table shows the format of the Environmental Error Logout Frame (MCLF) built by the console firmware used for Environmental Errors vectored through SCB entry 680h. Currently the only environmental fault supported is fan failure.

The "r" in the table below, when set, indicates that the error is retryable.

The "s" in the table below, when set, indicates that this is the second error.

The offset from the CEF below is shown for reference only.

Offset from

63

62

61

32

31

0

MCLF

CEF

R

s

SBZ

Frame Size

000h

068h

System Offset

EV6 Offset

008h

070h

MCHK Frame Revision

MCHK Code

010h

078h


Environmental Error Logout Frame - System Data

The operating system may choose to log additional information such as PCI configuration and various registers in the PCI-ISA bridge chip.

This table shows the format of the Environmental Error Logout Frame (MCLF) built by the console firmware used for Environmental Errors vectored through SCB entry 680h. Currently the only environmental fault supported is fan failure.

Offset from

System Data

MCLF

CEF

Software Error Summary Flags

000h

058h

CChip CPU0 Device Interrupt Request Register(DIR0)

008h

060h

CChip Miscellaneous Register (MISC)

010h

068h

PChip 0 Error Register (P0_PERROR)

018h

070h

PChip 1 Error Register (P1_PERROR)

020h

078h